Multi-Floor Zone Partitioning
Each functional area of the hotel is assigned to an independent alarm partition: ground-floor lobby back-of-house, guest floor service corridors per floor, kitchen and food storage, cash office, car park, plant room and business centre. Each partition can be armed, disarmed or bypassed independently — so a single trigger in the kitchen does not affect the arming status of any other area of the hotel.
🔔
Silent Duty Manager Notification
No audible siren on guest floors. All alarm events generate a silent push notification to the duty manager's app and an SMS to the security desk simultaneously. The duty manager acknowledges via app within the agreed window; if no acknowledgment is received, the ARC escalates automatically. Guest experience is preserved while security response is immediate and professional.
💻
BMS / BAS Integration
Alarm panel integrates with the hotel's Building Management System via dry-contact relay outputs or Modbus/BACnet protocol. Zone status, arm/disarm state, tamper alerts and power-supply events appear on the BMS engineering console alongside fire alarm, HVAC and elevator status — giving facilities staff a single-screen view of all building systems without a separate alarm monitoring terminal.
💎
Grade 3 for Boutiques & Money Exchange
Hotel jewellery boutiques and money exchange concessions require EN 50131 Grade 3: dual-technology anti-masking detectors, encrypted panel-to-ARC communication, tamper-protected conduit cabling and self-powered independent sounder. Quicknet provides the Grade 3 technical file — commissioning certificate, zone schedule and cable schedule — that you can submit to your insurer and licensing authority.
📋
Large-Panel Capability: Satel INTEGRA 256 & Bosch B8512
Medium hotels typically need 80–150 alarm zones; large resorts and hotel apartment towers may need 200–400. Satel INTEGRA 256 supports up to 256 zones, 256 outputs and 32 partitions natively. Bosch B8512G expands to 512 zones with expander modules. Both platforms support networked panel clusters for multi-building properties, with a single management interface across all panels.
🔒
ARC Monitoring Connection
Alarm signals can be connected to a licensed Alarm Receiving Centre of your choice; the ARC's own agreement sets the staffing, verification, police-liaison, response and reporting terms. Quicknet is not a monitoring station. For hotel groups with multiple properties, a multi-site agreement with the same ARC can give centralised reporting for the group security manager.
🚨
Panic & Duress Buttons at Reception and Housekeeping
Silent panic buttons at the front-desk counter and back-office, plus portable duress alerts carried by housekeeping and night-shift staff, let a team member trigger an immediate alert to security and the duty manager without alerting a guest or a potential aggressor. Each trigger is time-stamped and logged with the user and location, and can be configured as silent (no siren) or audible depending on hotel management policy.
🔑
PMS Integration for Guest Privacy
Optional integration with the hotel's Property Management System (Opera, Protel, Mews and similar platforms) automatically disarms a guest floor corridor zone for the duration of that guest's stay and re-arms it on checkout — reducing false alarms from guest movement while preserving full protection when a room is vacant. Requires coordination with the PMS vendor and hotel IT team.
🌴
Resort Exterior & Compound Perimeter Protection
For resort properties on Yas Island, Saadiyat Island and Al Raha Beach with multiple low-rise buildings, villas or chalets, beach frontage, pools and landscaped grounds, we add weatherproof outdoor beam detectors and perimeter motion sensors around the compound boundary, integrated with the hotel's main alarm panel and exterior CCTV — extending protection beyond the main building envelope.