Cat6, Cat6A, Cat7 and OS2 fibre cabling delivered across Abu Dhabi by Quicknet Computers — future-proof network backbone with OTDR-certified termination. Free site survey from our Mussafah HQ.
Abu Dhabi, the capital of the UAE, is one of the most demanding markets in the region for IT, security and ELV systems. Government-grade compliance, premium villa and tower fit-outs, regulated healthcare and education, oil & gas operations and a dense hospitality sector all run through Abu Dhabi-based contractors. Quicknet has been based in Abu Dhabi since 2012 and works on villas, offices and mixed-use buildings across the city.
For Structured Cabling specifically, Quicknet delivers across Abu Dhabi with a single accountable team — design, supply, installation, commissioning and ongoing AMC. Cat6, Cat6A, Cat7 and OS2 fibre cabling — engineered for Abu Dhabi business conditions and supported by our Mussafah workshop.
Materials and testing matter just as much as the design: we build around components including Belden, D-Link and Opterna, and every certified point is tested with Fluke/OTDR testers and documented to TIA-568 / ISO/IEC 11801 standards. Design consultation is free, most projects are scheduled within the same week, manufacturer-backed warranty options run up to 25 years, and an AMC covers ongoing moves, adds and changes.
Areas covered: Yas Island, Yas Marina, Yas Park, Noya Luma, Saadiyat Island, Al Reem, Reem Hills, Al Reeman 1, Al Reeman 2, Al Faya, Jubail Island, Al Bateen, Khalifa City, Mohamed Bin Zayed City.
It depends on the project. Applicable electrical, building, telecom and sector requirements are confirmed at the site survey.
Structured Cabling can be quoted for offices, campuses, data rooms, hotels, hospitals and industrial facilities across Abu Dhabi; the final scope is confirmed at the site survey.
Mussafah-dispatched engineers serve Abu Dhabi with same-week scheduled installations and 2-hour SLA response on critical incidents. Spare parts sourced for fast swap-out.
Quicknet Computers · Shabia ME-11, Mussafah, Abu Dhabi 8328, UAE · +971 50 852 9609
Quicknet designs, installs and tests structured cabling (Cat6, Cat6A and Cat7 copper and OS2 fibre) for offices and buildings in Abu Dhabi. The work covers cable routes, racks, patch panels, outlets and test results. We survey the building first and confirm the scope in a written quote.
Yes — Quicknet delivers Structured Cabling services across all major areas of Abu Dhabi including Yas Island, Saadiyat Island, Al Reem, Reem Hills, Al Reeman 1 & 2 (Al Faya), Jubail Island, Al Bateen, Khalifa City, Al Raha and Al Maryah Island. Our Mussafah-based engineering team handles site survey, design, supply, installation, commissioning and ongoing AMC.
For most Structured Cabling projects in Abu Dhabi we can attend a free site survey within 24–48 hours and submit a written quotation within 3 working days. Smaller installations can begin the same week; larger phased projects follow a documented design and approval timeline.
We take on Structured Cabling projects across Yas Island, Saadiyat Island, Al Reem, Reem Hills, Al Reeman 1 & 2 (Al Faya), Jubail Island, Al Bateen, Khalifa City, Al Raha and Al Maryah Island. Typical sites for this service include offices and corporate campuses, high-rise and mixed-use towers, hospitals and healthcare campuses, hotels and data rooms.
It depends on the project. At the site survey we confirm which electrical, building, telecom and sector requirements apply and document the installation accordingly; where an authority approval is needed, the licence holder or consultant files it and we prepare the technical documents.
Yes — Annual Maintenance Contracts include quarterly preventive visits, firmware updates, agreed-price spare parts and 2-hour response on Severity 1 incidents anywhere in Abu Dhabi. Combined CCTV + IT + access AMCs can be quoted together as one contract; ask for a combined quote.
Real reviews from the Google Business Profiles of Quicknet Computers across our three branches. Independent integrator since 2012, ADMCC approved, ISO 9001 and ISO 27001 certified.
Free site survey
Share a few details and your enquiry goes straight to our sales team.
PoE switch installation · UniFi network installation · HDMI extender installation
Networking & IT Infrastructure · Cybersecurity & Firewall · PABX & Communication Systems · AMC & Maintenance Services · Industrial IT — KIZAD & Mussafah · Free-Zone IT Setup.
Or view this service in another city: Structured Cabling in Mussafah · Structured Cabling in Al Ain · Structured Cabling in Dubai.
A structured cabling contractor delivers the cable plant that data, voice, Wi-Fi, CCTV and access control share. Quicknet's scope in Abu Dhabi covers:
Low-current (ELV) systems such as CCTV, access control and intercom can share the same cabling plant. See structured cabling cost in the UAE and ELV system integration.
| Item | Detail |
|---|---|
| Company | Quicknet Computers, in business since 2012 |
| Where | Mussafah headquarters (Shabia ME-11), Abu Dhabi branch office (Electra Street) and an Al Ain branch |
| Hours | Monday to Saturday 08:00 to 22:00, Sunday closed (Mussafah and Abu Dhabi office) |
| Scope | Cat6A copper to every outlet, OS2 single-mode or OM4 multi-mode fibre for backbones, patch panels, racks and labelling, a containment route agreed at the survey, Fluke and OTDR testing with PDF and CSV reports, as-built documentation and an optional AMC |
| Site survey | Free, arranged within 24 to 48 hours of an enquiry, followed by a written itemised quote |
| Price reference | Structured cabling cost per point in the UAE |
More answers about warranty, compliance, integration, response times and ongoing AMC support.
Structured cabling is the complete physical network backbone of a building or campus — the standardised system of copper (Cat6, Cat6A, Cat7) and fibre optic cables, patch panels, racks, faceplates, RJ45 outlets and fibre terminations that every connected device runs on. A structured cabling system usually includes: horizontal cabling (desk outlets to floor distributor), backbone cabling between floors or buildings (usually fibre), patch panels and racks in the IT room, labelled outlets, certified termination and pathway containment (trunking, trays, conduits). It carries data, voice (VoIP), CCTV, WiFi access points, access control, building management and AV — one cabling plant instead of several.
Timeline depends on outlet count and site readiness. As a rough guide: a small office of 20-40 outlets is typically 2-4 working days; a medium office of 50-150 outlets is 1-2 weeks; a multi-floor or campus deployment with backbone fibre is 3-6 weeks. Time includes site survey, design sign-off, trunking and containment, cable pulling, termination, OTDR/Fluke certification and labelled documentation. Authority approvals (where required) and Civil Defence sign-off can extend lead time on regulated buildings.
Cat6A copper is usually the right choice for the workstation horizontal runs (desk to floor distributor) because it carries 10 Gigabit up to 100 metres, supports PoE++ (90W) for AP, camera and access power, and is significantly cheaper to terminate. Fibre is usually the right choice for the backbone runs (between floors, between buildings, and to the data centre or server room) because it removes the 100-metre copper limit, carries 10/40/100 Gigabit speeds, is immune to electrical interference, and supports future bandwidth upgrades without rewiring. Most UAE offices we design end up with a Cat6A horizontal + OS2 single-mode fibre backbone hybrid — that is the 2026 default for buildings expected to last 10-15 years.
Verify (1) trade licence and Abu Dhabi presence — a Mussafah, Khalifa City or Al Ain office means engineers on call within an hour; (2) cable certification capability — ask if every cable run is Fluke or OTDR tested and whether you receive the test report; (3) brand independence — integrators carrying Belden, Norden, Commscope and Panduit are normally preferable to a single-brand-locked installer; (4) ISO 9001 and ISO 27001 — the genuine ones are auditable and indicate a quality and security management system; (5) AMC capability — moves, adds, changes (MAC) and emergency response after handover matter more than the install price; (6) reference projects you can verify, not anonymous claims. Any quote that excludes cable certification is a future cost trap.
Yes. Quicknet supplies and installs Norden server cabinets and network racks from 6U wall-mount to 42U floor-standing, with PDUs, fans and cable management, after a free survey and written quote. See Norden cabinets in Abu Dhabi and the network rack and cabinet guide.
A structured cabling contractor installs the cable plant that data, voice, Wi-Fi, CCTV and access control share: Cat6A copper to each outlet, OS2 single-mode or OM4 multi-mode fibre for backbones, patch panels, racks, labelling and containment routes, then tests every link. Quicknet does the design, installation, testing and documentation after a free survey.
A structured cabling system is a standards-based cable plant built to TIA-568 and ISO/IEC 11801: a main distribution room, backbone cabling between floors, horizontal cabling to every outlet, patch panels and work-area outlets, all labelled and tested. One system carries data, voice, Wi-Fi, CCTV, access control and other IP devices.
Low current, also called extra-low voltage (ELV), covers systems that run below 50 V AC: data and voice networks, CCTV, access control, intercom, fire alarm and public address. Structured cabling is the shared data cabling base for many of them, and Quicknet integrates ELV systems on one structured cabling backbone. See ELV system integration.
Quicknet publishes cost per point: AED 250-380 for Cat6, AED 350-540 for Cat6A, AED 480-720 for Cat7 and AED 90-180 for OM4 multi-mode fibre plus termination. Everything else is quoted in writing after a free site survey. See structured cabling cost in the UAE.
A written proposal with a bill of materials: outlet count and cable category, backbone fibre, the containment route, patch panels and racks, testing and documentation, and an optional warranty and AMC. The price depends on the cable category, the route and building, backbone fibre, testing and warranty. A free survey comes first.
Containment is the tray, trunking, conduit or riser that carries the cable. Quicknet plans the containment route at the survey and pulls the cable through the agreed containment: trunking, trays, conduit or existing risers. Electrical works are coordinated with a licensed electrical contractor.
Labelled patch-panel and outlet documentation, as-built drawings and the Fluke or OTDR test reports as PDF and CSV. The certified test reports become the warranty registration package, and an AMC can be added for later moves, adds and changes.
Yes. Data centre cabling follows its own standards for density, speed and bend control; see our data centre cabling standards guide. Quicknet designs, installs, tests and documents the cabling after a free survey.
They describe the same cable plant: the wiring from wall outlets to patch panels and network equipment. "Cabling systems" is the general term, and structured cabling is the standards-based version (TIA-568 and ISO/IEC 11801) with labelling, testing and documentation. Quicknet quotes network wiring, infrastructure cabling and structured cabling as one certified scope.
Quicknet Computers has three branches: the Mussafah HQ (Shabia ME-11), the Abu Dhabi branch office on Electra Street and the Al Ain branch. A free site survey is arranged within 24 to 48 hours of an enquiry, followed by a written quote. Call +971 50 852 9609.
Yes. One team covers design, supply, installation, testing, certification and documentation, and an annual maintenance contract can be added for later moves, adds and changes. Electrical works are coordinated with a licensed electrical contractor.
Yes. We survey and test the existing cabling to see what meets the category you need, then propose what to keep, re-terminate or replace. We typically extend existing patch panels and racks rather than replace them, and record everything in your existing labelling scheme.
Adjacent services, locations and guides — jump to anything relevant.
Cat5e vs Cat6 vs Cat6A vs Cat7 vs Cat8 →
Patch panel installation guide →
Network rack and cabinet guide →
How Structured Cabling Works →
Data Centre Cabling Standards →
PoE (Power over Ethernet) Explained →
Cable Testing — Fluke and OTDR →
Etisalat and du Approval Cabling →
Commscope (Systimax + Uniprise + AMP) →
Panduit — TX6A, OptiCom, Net-Access →
Legrand LCS3 — incl. BTicino + KNX →
Systimax — premium Commscope tier →
Furukawa Electric — Laserway, Fitel →
AMP NetConnect — legacy compat →
Hyperline — mid-market value →
Siemon — TERA Cat7A, BICSI leader →
Cost and buying guide: Structured Cabling Cost in the UAE
Read next: Cable tray, trunking and conduit for UAE buildings: types, fill limits and firestopping
Read next: UTP vs STP vs FTP: shielded and unshielded network cable, cable codes and grounding
Quicknet Assistant
Common questions
Hi! 👋 I'm the Quicknet Assistant.
I can answer common questions about our services. What can I help you with today?