Intesis AC and VRF Gateways for BMS and Smart-Home Integration in the UAE
Interfaces that let split, ducted and VRF air conditioning speak BACnet, Modbus RTU, WiFi or cloud control, so every indoor unit can be scheduled, monitored and optimised from one building or home system.
Bringing air conditioning into the building management conversation
In the UAE, air conditioning is usually the largest energy load in a villa, office or hotel, yet many systems are still run from individual wall controllers that nobody can see centrally. An Intesis interface removes that blind spot. It sits on the manufacturer's own indoor-unit or VRF bus and presents each unit's status and set points to the controller you already use, whether that is a BACnet BMS, a Modbus PLC or a home-automation processor.
The range is organised by air-conditioning brand and by target protocol. Daikin domestic and VRV/Sky systems have BACnet IP/MSTP, BACnet MS/TP, Modbus RTU, WiFi (ASCII) and AC Cloud Control variants. Mitsubishi Electric Domestic, Mr.Slim and City Multi, Mitsubishi Heavy Industries FD and VRF, Toshiba VRF and Digital, Panasonic Etherea, ECOi and PACi, LG VRF, Samsung NASA and non-NASA, Fujitsu RAC and VRF are covered in similar combinations, while Hitachi, Midea, Hisense and Bosch systems have BACnet or Modbus RTU options.
Where an air conditioner has no accessible service bus, the Universal IR interfaces send the unit's infrared commands instead, bridging ordinary wall splits to Modbus RTU, WiFi or cloud control. Quicknet selects the correct part number for your indoor-unit model, wires it on site, maps the data points into your BMS or smart-home programme and commissions each zone so that schedules, set-back rules and alarms behave predictably from the first day.
55 products · Intesis
Intesis HVAC Interface and Gateway Range
Browse Intesis interfaces by air-conditioning brand and protocol. Share your indoor-unit model numbers and we will confirm the exact part for your project.
Product names, specifications and images are provided for identification; confirm current model availability, finishes and datasheets with our team before ordering.
Selection guide
Choosing the right Intesis HVAC interface
Match the AC family first
Intesis part numbers are specific to the air-conditioning manufacturer and product line, for example Daikin domestic versus Daikin VRV and Sky, or Panasonic Etherea versus ECOi and PACi. We confirm indoor and outdoor model numbers on site before ordering, because the connection point and data map differ between families.
Choose the protocol your system speaks
BACnet IP or MS/TP suits most commercial BMS head-ends and Modbus RTU suits PLCs and many energy platforms, while the WiFi (ASCII) home-automation variants and AC Cloud Control devices are aimed at smart-home processors and app control. Matching the controller's native protocol avoids a second translation layer.
One interface per unit or per system
Domestic and split interfaces typically connect to a single indoor unit, whereas VRF gateways can address several indoor units on one bus. Counting indoor units, and noting which share an outdoor system, determines how many interfaces are needed and how the points list is structured in the BMS.
Agree the data points early
Useful points usually include on/off, mode, set point, fan speed, room temperature and error codes. Agreeing this list with the MEP consultant or facility manager before commissioning keeps graphics, alarms and trend logs consistent across floors, villas or tenancy areas.
Legacy and non-networked splits
Older wall-mounted splits without a service bus can still be integrated through the Universal IR interfaces. They suit enclosed rooms such as offices, majlis or bedrooms, where the IR emitter has a clear line to the indoor unit and occupants accept centrally managed set points.
Service Areas: Abu Dhabi and Al Ain
Quicknet supplies, installs, programmes and supports these products from its Mussafah head office and its branches in Abu Dhabi and Al Ain, and takes on projects in Dubai and other emirates on a project basis (Quicknet has no office there). Site surveys, installation and after-sales support cover Abu Dhabi city and its island and suburban communities (including Saadiyat, Yas, Al Reem, Khalifa City and Mussafah), and Al Ain. Dubai villa communities and commercial buildings are quoted on a project basis by our Abu Dhabi team.
Send us your drawings, room list or model numbers. Our engineers confirm compatibility, prepare a written, itemised quotation and handle supply, installation, programming and after-sales support in Abu Dhabi and Al Ain, and on a project basis elsewhere in the UAE.
Intesis AC and VRF Gateways for BMS and Smart-Home Integration in the UAE — Frequently Asked Questions
Which air-conditioning brands can these Intesis interfaces connect?+
The range listed here covers Daikin (domestic and VRV/Sky), Mitsubishi Electric (Domestic, Mr.Slim and City Multi), Mitsubishi Heavy Industries, Toshiba, LG, Panasonic, Samsung, Fujitsu, Hitachi, Midea, Hisense and Bosch commercial and VRF systems, plus Universal IR interfaces for units without a service bus. Compatibility depends on the exact model series, so we always check indoor-unit model numbers before recommending a part.
Should we use BACnet or Modbus for the BMS?+
Use whatever the building's head-end speaks natively. Most commercial BMS platforms prefer BACnet IP or MS/TP, while many PLCs, energy-monitoring systems and some controllers use Modbus RTU. Both carry the same practical data, such as on/off, mode, set point and faults. We confirm the protocol with your MEP consultant or controls contractor before ordering.
Can a villa smart-home system control VRF air conditioning?+
Yes. The home-automation and WiFi (ASCII) interfaces are intended for smart-home processors, so a villa system can show each room's AC status on keypads, touch screens and apps and include it in scenes such as Away or Night. For KNX-based villas, the KNX variants on our KNX, BACnet and Modbus gateway page are usually the cleaner choice.
Are these interfaces suitable for UAE conditions?+
The interfaces are installed indoors, normally near the indoor unit or inside a ventilated control panel, so they are not exposed to outdoor heat. We mount them in accessible, conditioned locations, label every connection and keep the wiring separate from mains cabling. That protects reliability through the summer and makes future servicing straightforward.
Who programmes and commissions the gateway?+
Quicknet configures each interface, maps its data points to your BMS or automation controller, tests every unit's commands and feedback, and hands over a points list with the as-built documentation. We can also work alongside an existing controls contractor where they own the BMS head-end and we deliver the HVAC integration layer.
Is support available after handover?+
Yes. Our maintenance and AMC support covers configuration backups, point verification after AC servicing or unit replacement, fault diagnosis and changes when rooms are re-planned, so the BMS keeps reporting accurately as the building evolves. Lead times for specific part numbers vary by model, so we confirm availability when we issue the written quotation.