Intesis KNX, BACnet and Modbus Protocol Gateways in the UAE
Protocol translation hardware that joins KNX, BACnet, Modbus, LonWorks, DALI-2, M-Bus, OCPP and VRF air conditioning into one coherent building or villa control system.
Modern UAE buildings rarely run on a single protocol. Lighting may be DALI-2, room control KNX, chillers and meters Modbus or M-Bus, older plant LonWorks, and the central BMS BACnet. Without translation, each system is managed on its own screen and its data stays isolated. A correctly sized gateway exposes the points each system needs to the others, so a facility team can monitor, trend and alarm from one head-end.
This page lists the Intesis gateway range we can supply. Client and server applications link BACnet IP and MS/TP devices to KNX TP, Modbus TCP and RTU or ASCII systems, KNX TP to Modbus and ASCII, and Modbus devices to BACnet or KNX, in several point capacities. LonWorks TP/FT-10 to BACnet gateways are offered from 100 up to 3,000 data points. DALI and DALI-2 interfaces bring lighting drivers and sensors onto Modbus TCP or BACnet IP, while M-Bus gateways integrate utility meters into Modbus or KNX.
The range also includes VRF-to-KNX interfaces for Daikin, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, LG, Panasonic, Fujitsu, Hitachi, Hisense, Haier and Midea systems, MQTT gateways for cloud and IoT platforms, OCPP-to-Modbus gateways for EV charging points, and EtherNet/IP and PROFINET to BACnet gateways for industrial plant. Quicknet designs the points list, configures each gateway and commissions the integration end to end.
66 products · Intesis
Intesis Protocol Gateway Range
KNX, BACnet, Modbus, LonWorks, DALI-2, M-Bus, OCPP, MQTT and VRF gateways. Send us your points list or system schematic and we will recommend the right model and capacity.
Product names, specifications and images are provided for identification; confirm current model availability, finishes and datasheets with our team before ordering.
Selection guide
Specifying a protocol gateway correctly
Define direction and roles
Every gateway has a client or master side and a server side. Decide which system reads and writes and which exposes data. A BACnet client to Modbus server application, for example, lets a Modbus master read and write BACnet devices, while a Modbus master to BACnet server application presents Modbus devices to a BACnet BMS.
Size by data points
Several gateways come in point-count capacities, such as the LonWorks to BACnet models from 100 to 3,000 points. Build the points list before ordering and leave headroom for future plant, because moving to a larger capacity later usually means replacing the gateway.
KNX and KNX Secure
KNX is an open standard (ISO/IEC 14543-3) widely used for villa and office room control. The gateways listed here connect KNX TP lines to Modbus, BACnet or ASCII systems, and the Universal IR air-conditioner interface is offered in a KNX Secure version for projects that require encrypted communication.
Lighting and metering
DALI-2 gateways with one or two channels expose drivers and light sensors to Modbus or BACnet, useful for energy reporting and scheduling. M-Bus gateways collect water, heat and electricity meter data for tenancy billing and sustainability dashboards without a separate metering server.
EV charging and industrial plant
OCPP 1.6 to Modbus gateways bring EV charge points into the BMS so load and status are monitored alongside other plant. EtherNet/IP and PROFINET to BACnet gateways connect industrial controllers in warehouses and utility buildings to the facility management system.
Commissioning discipline
A gateway is only as good as its mapping. We document each point with its source address, data type, scaling and alarm behaviour, test reads and writes in both directions, and hand over the configuration file so the integration can be restored or extended quickly.
Service Areas: Abu Dhabi and Al Ain
Quicknet supplies, installs, programmes and supports these products from its Mussafah head office and its branches in Abu Dhabi and Al Ain, and takes on projects in Dubai and other emirates on a project basis (Quicknet has no office there). Site surveys, installation and after-sales support cover Abu Dhabi city and its island and suburban communities (including Saadiyat, Yas, Al Reem, Khalifa City and Mussafah), and Al Ain. Dubai villa communities and commercial buildings are quoted on a project basis by our Abu Dhabi team.
Send us your drawings, room list or model numbers. Our engineers confirm compatibility, prepare a written, itemised quotation and handle supply, installation, programming and after-sales support in Abu Dhabi and Al Ain, and on a project basis elsewhere in the UAE.
Intesis KNX, BACnet and Modbus Protocol Gateways in the UAE — Frequently Asked Questions
What is the difference between a BACnet gateway and a Modbus gateway?+
They present data to different target protocols. A BACnet gateway exposes devices to a BACnet BMS, the common head-end protocol in commercial buildings. A Modbus gateway exposes devices as Modbus TCP or RTU registers, which suits PLCs, energy platforms and many controllers. Several Intesis applications work in either direction, so the choice depends on which system is reading and which is being read.
Can KNX lighting and room control be integrated into a BACnet BMS?+
Yes. A BACnet head-end can read and command KNX group addresses such as lighting states, blind positions and room temperatures through a KNX to BACnet server gateway, with the model confirmed per project; where the BMS uses Modbus, the KNX TP to Modbus server application does the same. We agree the group address list with the KNX programmer so both systems stay consistent after future changes.
How many data points do we need?+
Count every value the BMS must read or write, including status, commands, set points and alarms, then add a margin for expansion. On a LonWorks or Modbus integration this can grow quickly. Capacities on the listed gateways range from small applications to several thousand points, and we size the model after reviewing your schedules and schematics.
Can EV chargers be monitored by the building management system?+
Yes, where the chargers use OCPP 1.6. The OCPP to Modbus gateways listed here expose charger status and energy data to a Modbus-based BMS or energy platform, and one model handles up to 20 chargers with up to seven connectors each. This is useful in car parks where charging load must be managed alongside other building services.
Do you work with an existing BMS contractor's head-end?+
Yes. Many UAE projects already have a controls contractor responsible for the BMS head-end and graphics. Quicknet can deliver the gateway, field-side wiring, configuration and point mapping, then coordinate testing with the head-end team so graphics, trends and alarms are built on a verified points list.
What support is available after commissioning?+
We keep a copy of each gateway configuration and offer AMC and on-call support for fault diagnosis, firmware updates and point additions. We can also revisit the mapping when plant is replaced or tenancy layouts change. Availability of specific part numbers varies, so we confirm lead times when we issue the written quotation.