Skip to main content

National Manual for Surveillance Systems V3.0 (2026): Requirements by Category

A plain-language guide to the 33 facility categories, what is mandatory or optional, and what it means for CCTV in Mussafah, Abu Dhabi and Al Ain.

By Quicknet Engineering Team, Quicknet Computers · Reviewed by Jenson Cleetus · Last reviewed: 23 November 2026
Graphic: the 33 facility categories of the UAE National Manual for Surveillance Systems V3.0. 19 categories need 30 days of video storage, 9 need 90 days and 5 need 180 days; the control room, ANPR and AI analytics are marked mandatory for 14, 14 and 13 categories
Numbers from the category table of the manual. Some Mandatory flags apply to part of a category only (for example hospitals).
The manual

What the manual is

The National Manual for Surveillance Systems V3.0 (2026) is a unified technical and regulatory framework. Its stated objectives include defining technical standards, improving control room efficiency, defining operational controls, enabling technical inspection and approvals, and supporting AI in surveillance. The cover lists the concerned authorities, including Abu Dhabi Police and the Security Industry Regulatory Agency (SIRA); the disclaimer says the document belongs to the Monitoring and Control Centre (MCC).

Section 4 says the listed government and private entities shall comply with the manual, and that the design, installation, operation and maintenance of surveillance systems shall be carried out by one of the entities licensed by the concerned authorities.

Read this first: the disclaimer says the Arabic text prevails if it differs from the English, and that MCC may modify the manual at any time without notice. This page is an installer summary, not legal advice. Confirm the current version and your category with the MCC. The MCC notification we reviewed refers to the “National Guide for Video Surveillance Systems”; this page summarises the National Manual for Surveillance Systems V3.0 (2026), so ask the MCC which version applies to you. The disclaimer also says the concerned authorities may ask for added coverage areas or more cameras, and that the entity bears all resulting costs.

Find your category

The 33 categories: storage days, control room, ANPR and AI

Each row is copied from the category table. Mandatory and Optional are the manual's own words. Some rows carry a limit, for example hospitals only or entertainment venues only. The manual adds that the concerned authorities may add categories, may set longer storage (minimum 30 days) and may change the control room, ANPR and AI requirements, and that the ANPR requirement applies only where the facility has a designated parking area.

Source: category table in the manual (section 4)
#CategoryGroupStorageControl roomANPRAI analyticsOur page
1Monetary and financial institutions (bonds and cheques)A30 daysOptionalOptionalOptional-
2Stores and warehouses of precious, hazardous and medical materialsA30 daysOptionalOptionalOptionalPage 1Page 2
3Commercial stores specified by the concerned authoritiesA30 daysOptionalOptionalOptionalPage 1
4Key cutting storesA30 daysOptionalOptionalOptional-
5Vehicle dealerships, showrooms and vehicle rental storesA30 daysOptionalOptionalOptionalPage 1Page 2
6Government authoritiesA30 daysMandatoryOptionalOptionalPage 1
7Wedding and events hallsA30 daysOptionalOptionalOptionalPage 1
8Cinema complexesA30 daysMandatoryOptionalOptionalPage 1
9Money exchangersA90 daysOptionalOptionalOptionalPage 1
10Educational entities (nurseries, kindergartens, schools, colleges, universities)A90 daysMandatory (Except nurseries)Mandatory (Except nurseries)Mandatory (Except nurseries)Page 1Page 2
11Precious metals and gemstones manufacturing, sales and repair storesA90 daysOptionalOptionalOptionalPage 1
12Public gathering spaces and parksA30 daysOptionalOptionalOptional-
13Marinas, slipways, boat and ship docks, ferry terminals, water taxi stationsA30 daysOptionalOptionalOptionalPage 1
14Bus stop sheltersA30 daysOptionalOptionalOptional-
15Entertainment venues, gaming centres, food truck areas, sports clubsA30 daysMandatory (Entertainment venues only)Mandatory (Entertainment venues only)Mandatory (Entertainment venues only)Page 1Page 2
16Football sports stadiumsA30 daysMandatoryMandatoryMandatoryPage 1
17Healthcare entities (hospitals, centres, clinics, pharmacies, blood banks)A30 daysMandatory (Public and private hospitals)Mandatory (Public and private hospitals)Mandatory (Public and private hospitals)Page 1Page 2Page 3
18Buildings designated for vehicle parkingA30 daysOptionalMandatoryOptionalPage 1Page 2
19Residential compounds, buildings and commercial buildingsA90 daysOptionalMandatoryOptionalPage 1
20Fuel stations, EV charging stations, vehicle inspection centresA90 daysOptionalMandatory (Fuel and EV charging stations only)Mandatory (Fuel and EV charging stations only)Page 1
21Exhibition hallsA90 daysMandatoryMandatoryMandatoryPage 1
22Labor accommodationA90 daysMandatoryMandatoryMandatoryPage 1
23Places of worship and religious educational centresA30 daysOptionalOptionalOptionalPage 1
24Holiday homesA30 daysOptionalOptionalOptionalPage 1
25Firearm stores and warehousesA30 daysOptionalOptionalOptional-
26Shooting rangesA180 daysMandatoryMandatoryMandatory-
27Public welfare associationsA30 daysOptionalOptionalOptional-
28MuseumsB90 daysMandatoryMandatoryMandatoryPage 1
29Places of public transport and portsB90 daysMandatoryMandatoryMandatoryPage 1
30Hotels, hotel apartments and limited residential accommodationB180 daysMandatoryMandatoryMandatoryPage 1
31Shopping mallsB180 daysMandatoryMandatoryMandatoryPage 1
32BanksB180 daysOptionalOptionalMandatoryPage 1
33Digital data storage and video recording centresB180 daysMandatoryOptionalOptionalPage 1
Group A and Group B

What the two groups change

Categories 1 to 27 are Group A and categories 28 to 33 (museums, public transport and ports, hotels, shopping malls, banks, data and video recording centres) are Group B. Most clauses apply to both. The tick columns show that these clauses apply to Group B only:

  • Recording storage on at least RAID 5 with enterprise drives of at least 7200 RPM, 30 days of failover storage, one failover server for every four recording servers, no single point of failure and failover within two minutes
  • Continuous 24/7 recording (Group A may use motion-based recording with a 10-second pre-event buffer, but identification cameras must always record continuously)
  • A Windows-based video management system that supports multicast streams, layer 3 stackable core switches, and physical tamper sensors on the main racks
  • Alerts for repeated failed logins, a tamper-proof audit trail forwarded to a SIEM or SOC, protection of exported files, vendor security documentation, and a secure backup of configurations

Group A (including vehicle rental, showrooms, schools, hospitals, residential buildings, parking, fuel stations and labour accommodation) still carries the core camera, recording, security and maintenance clauses below.

Technical clauses

Cameras, recording and storage at a glance

Group A and B unless marked in the Group A and Group B section above
AreaWhat the manual says
CamerasFixed IP cameras only; minimum 1920 x 1080; infrared; varifocal motorised lens for identification cameras or when mounted at 4 m or above; dual streams; ONVIF Profile S; SNMP v3 (v1 and v2c prohibited); H.264 or newer; WDR 110 dB or equivalent; auto iris or equivalent; IP66 for outdoor. Adding or removing a camera needs prior approval from the concerned authorities.
Pixel densityIdentification 500 pixels per metre; recognition 125; observation 63.5; detection 30; vehicle view and ANPR 500.
Frame rateIdentification, vehicle view and ANPR 25 fps; recognition, observation and detection 12 fps.
RecordingSupported operating system, ONVIF, integration with the concerned authority systems through API or SDK (supplier bears the development cost), more than two NVRs managed through a central management system (Group A clause), dedicated LAN port, camera name, date and time on the stream, CSV/TXT reports, export playable in free Windows software, automatic resume after a power cut, first in first out overwrite.
StorageCapacity for the retention period plus at least 20% spare. Retention is the number of days in the category table (30, 90 or 180).
Power and displayUPS for the monitoring and control system with at least 30 minutes of operation; monitoring screens of at least 21 inches built for 24/7 use.
NetworkMAC address filtering and unused ports disabled; SNMP v3 on switches; a surveillance network dedicated to and isolated from other networks.
Control room (section 2)

Monitoring and control room rules

The control room is Mandatory only for the categories marked so in the table above. Where it is required, the manual sets these rules:

  • Access is restricted to employees, system operators and authorised visitors; photography is prohibited inside.
  • A record of entry and exit (date and time) of employees, operators and authorised visitors.
  • Internal and external communication systems and a dedicated hotline to the competent authorities for reporting incidents.
  • Compliance with health and safety requirements; the room is isolated from visitor gathering areas, reception areas and crowded corridors.
  • A door access control system and surveillance cameras inside the room.
  • No camera-equipped electronic devices inside (mobile phones, tablets, smartwatches); no laptop without prior approval; no device removed without prior approval.
  • Backup power for the room for 30 minutes in a major power failure, and a UPS for the monitoring and control system of at least 30 minutes.
Operations and security

Operational controls, security and maintenance

  • Annual maintenance contract: the entity shall keep an annual maintenance contract for the monitoring and control devices with a company registered by the concerned authorities, covering both corrective and preventive maintenance.
  • Faults: inform the concerned authorities of a technical issue and solve it within one working day; if it cannot be fixed, say why.
  • Cleaning and records: clean indoor and outdoor cameras periodically and record all maintenance and cleaning work with names, date and time.
  • Signage: a visible sign in Arabic, English and Urdu, with icons, that is kept in good condition.
  • Drawings and documents: DWG drawings on request, cameras named on the drawings, colour-coded fields of view, as-built drawings, cable routing, network diagram, operating manual and configuration details.
  • Footage: extracting footage needs an official letter from the competent or concerned authorities; deleting footage needs prior approval; keep a record of every extraction.
  • Restrictions: hidden cameras are prohibited; wireless cameras, audio recording, PTZ cameras and fields of view beyond the entity boundary need prior approval; cameras must support privacy masking.
  • Cyber security: no exposure to the public Internet and no cloud use without prior approval; remote maintenance disabled by default; unique non-default credentials; passwords of at least 11 characters; role-based access; lockout after more than five failed attempts; NTP set to UAE time (UTC +4); firmware and antivirus kept current.
ANPR (section 4)

Automatic number plate recognition requirements

The ANPR requirement is Mandatory for educational entities (except nurseries), football stadiums, hospitals, buildings designated for vehicle parking, residential compounds and buildings, fuel and EV charging stations, exhibition halls, labour accommodation, shooting ranges, museums, public transport and ports, hotels and shopping malls, and only where a designated parking area exists. For the other categories it is Optional.

  • Fixed IP cameras, ONVIF Profile S, IP66 outdoor, at least 1920 x 1080, at least 25 fps (PAL) or 30 fps (NTSC), infrared
  • One of three architectures: centralised on-premises server, edge AI device, or smart camera with embedded ANPR
  • Accuracy of at least 99% for vehicle detection and 98% for plate recognition, day and night, for GCC plates; new plates added within 90 days
  • Search by camera, plate number, source, code, colour, category, date and time; CSV reports with vehicle and plate images; images stored as JPEG
  • Alerts for camera failure, processing unit failure, network failure, storage threshold, CPU or memory threshold and data backlog
  • Integration with the concerned authority systems through API or SDK; UPS of at least 30 minutes; cloud only with prior approval; maintenance and cleaning recorded

See our ANPR and number plate recognition page.

AI video analytics (section 5)

AI video analytics requirements

AI analytics is Mandatory for educational entities (except nurseries), entertainment venues, football stadiums, hospitals, fuel and EV charging stations, exhibition halls, labour accommodation, shooting ranges, museums, public transport and ports, hotels, shopping malls and banks. For the other categories it is Optional.

  • Approved architectures: centralised server (CPU or GPU), dedicated AI appliance, or edge AI cameras
  • Deployed inside the surveillance network only; all event video, analytics data and metadata stored on-premises in the control room; cloud or external hosting only with prior written approval
  • At least 90% detection accuracy, working in day, night, low-light and infrared; calibration and masking to reduce false alarms
  • Real-time notifications with date and time (NTP), camera name and location, event type and a snapshot or clip reference; at least 30 days of video and analytics data
  • AES-256, TLS 1.2 or higher, role-based access and multi-factor authentication for administrators; immutable event logs
  • Analytics types in the manual: face detection, people counting, motion, intrusion, loitering, violent behaviour, slip and fall, dangerous objects, crowd, fire, unauthorised parking, wrong-way driving, camera tampering, and object left or removed

See our AI video analytics page and AI CCTV page.

Coverage (section 3)

Mandatory coverage areas and levels

Every entity must cover the mandatory public areas at the stated level: identification for entrances and exits, emergency exits, control rooms and main equipment racks, cash handling areas and safes; recognition for lobbies, corridors, lifts and stairs, loading areas, kitchens and similar areas; observation for the building perimeter, ramps and assembly areas; detection for landscape and parking areas; and vehicle view or plate reading for vehicle entrances and exits and passenger drop-off. Store rooms, utility rooms, back-of-house areas and similar spaces are optional operational coverage. Section 3 then lists extra areas for each category.

Coverage by category

Extra coverage areas for your category

Section 3 lists extra areas for each category on top of the general mandatory areas. The number after each category is its number in the table above. Rooms and areas not listed are optional operational coverage.

Source: manual section 3, part 2 (coverage by category)
CategoryLevelAreaStatus
Commercial stores specified by the authorities (3)RecognitionInside the liquor storage areaMandatory
Warehouses of precious, hazardous and medical materials (2)RecognitionFull coverage of stores and warehouses, including between racks and shelves, and the surrounding areaMandatory
Money exchangers (9)RecognitionGeneral coverage of teller countersMandatory
Money exchangers (9)RecognitionAll offices (single and shared)Optional
Educational entities (10)RecognitionSleeping and food preparation areas in kindergartens and nurseriesMandatory
Educational entities (10)RecognitionAll educational rooms in nurseries, kindergartens, schools, colleges, universities and institutionsMandatory
Educational entities (10)RecognitionMultipurpose halls and roomsMandatory
Educational entities (10)RecognitionSupervisor and teacher officesOptional
Precious metals and gemstones stores (11)RecognitionGeneral shop coverage including display tables, showcases and selling areas; precious items stores; workshopsMandatory
Precious metals and gemstones stores (11)RecognitionTrial roomsOptional
Healthcare entities (17)RecognitionInside the pharmacy, blood banks, drug warehouse and all medical stores; ambulance drop-off area; infant nursery rooms; nursing stations; medical records roomMandatory
Healthcare entities (17)RecognitionSterilization (CSSD) rooms; physiotherapy rooms (men and children only)Optional
Buildings for vehicle parking (18)IdentificationPedestrian entrances to the buildingMandatory
Buildings for vehicle parking (18)DetectionInside the building to cover the vehicle parking area; internal drivewaysMandatory
Residential compounds and buildings, commercial buildings (19)DetectionPublic places available to the public; internal driveways of residential compoundsMandatory
Fuel stations, EV charging stations, vehicle inspection centres (20)IdentificationEntrances and exits of convenience stores; main tank refuelling points (petrol, diesel, gas); lube storesMandatory
Fuel stations, EV charging stations, vehicle inspection centres (20)RecognitionDispenser fuelling points; inside the convenience store; car wash and vacuum bay; lube bay; vehicle inspection areas; EV charging area; indoor seating; drive-through of convenience storesMandatory
Fuel stations, EV charging stations, vehicle inspection centres (20)DetectionInternal drivewaysMandatory
Labor accommodation (22)RecognitionLaundry room; training roomMandatory
Hotels and limited residential accommodation (30)IdentificationPassengers' entrances and exits of boat docksMandatory
Hotels and limited residential accommodation (30)RecognitionGeneral outdoor coverage of villas and chalets; boats and marina pavements; baggage and valuables roomsMandatory
Banks (32)RecognitionGeneral coverage of the teller counterMandatory
Banks (32)RecognitionAll offices (single and shared)Optional
Digital data storage and video recording centres (33)RecognitionThe entire data centre hall including between racks and the video recording centre; UPS, battery and generator rooms; server room; network operations centreMandatory
Digital data storage and video recording centres (33)RecognitionBMS rooms, ELV rooms and transformer roomsOptional
AI analytics by category

Required AI analytics for specific categories

Besides the general analytics for all categories (section 5, part 2.1), the manual lists these analytics for specific categories. They matter where AI analytics is Mandatory.

Source: manual section 5, part 2.2 (analytics by category)
CategoryAnalyticsAreas of application
Educational entities (10)Violent behaviour detection; dangerous objects detectionAll educational rooms; indoor and outdoor play areas (violent behaviour also in multipurpose halls)
Entertainment venues (15)Object left or removed detection; slip and fall detectionIndoor and outdoor playing areas; audience seating area
Football sports stadiums (16)Violent behaviour; dangerous objects; object left or removedAudience seating area
Healthcare entities (17)Motion detection; unauthorised parking detectionMedical records room; ambulance drop-off area
Fuel stations, EV charging stations, vehicle inspection centres (20)Object left or removed detection; unauthorised parking detectionDispenser fuelling points; main tank refuelling points (petrol, diesel, gas)
Museums and exhibition halls (21, 28)Motion detection; violent behaviour; dangerous objects; object left or removedPrecious material stores (motion); indoor and outdoor venues, galleries and exhibition areas
Shooting ranges (26)Motion detection; violent behaviour detectionWeapon and ammunition stores (motion); shooting cabins, indoor and outdoor shooting areas, training areas
Hotels and limited residential accommodation (30)Face detectionVisitors' entrances and exits of boat docks
Cost

What does the work cost?

Starting from AED 1,000+ for surveillance projects covered by the National Manual for Surveillance Systems: CCTV installation or compliance upgrade, ANPR, AI video analytics, and recording and storage. This is a starting reference, not a fixed price, and it applies only to these manual-related projects, not to other Quicknet services. The final price depends on the facility category, equipment, camera quantity and project scope, and is confirmed in a written quotation after the site survey.

Quicknet

How Quicknet helps in Mussafah, Abu Dhabi and Al Ain

Quicknet Computers is an ADMCC-approved CCTV installer with branches in Mussafah, Abu Dhabi City and Al Ain, in business since 2012. We survey your premises against your category, quote in writing, install and upgrade IP cameras, NVRs and storage, supply the supporting network cabling and door access works, and keep the system under an annual maintenance contract. No price is published here because it depends on the category, the camera count and the scope.

Request a site survey for your category

Tell us the facility type, location (Mussafah, Abu Dhabi or Al Ain), the system you have now, the number of cameras and your timeline. We send a written scope and quotation.

Book a CCTV site survey ‎+971 50 852 9609‎ WhatsApp now
Enquiry

Request a CCTV site survey and quotation

Tell us about the facility. A few details let us prepare the right scope before the survey. Starting from AED 1,000+ for manual-related surveillance projects; the final price depends on the facility category, equipment, camera quantity and project scope.

CCTV survey and quotation request

Prefer to talk? Mobile / WhatsApp: ‎+971 50 852 9609‎ · Landline: ‎+971 2 553 1474‎

FAQ

Frequently Asked Questions

What is the National Manual for Surveillance Systems V3.0?
It is the 2026 version of the UAE national manual that sets technical specifications, operational controls, coverage areas, ANPR and AI video analytics requirements for 33 categories of facility. The disclaimer says it belongs to the Monitoring and Control Centre and that MCC may modify it without notice.
Which categories must have a monitoring and control room?
Mandatory for government authorities, cinema complexes, educational entities (except nurseries), entertainment venues, football stadiums, hospitals, exhibition halls, labour accommodation, shooting ranges, museums, public transport and ports, hotels, shopping malls and digital data storage and video recording centres. Optional for the rest.
Is ANPR mandatory for residential buildings and car parks?
Yes under the category table: residential compounds, buildings and commercial buildings, and buildings designated for vehicle parking are marked Mandatory for ANPR, and the manual says the ANPR requirement applies only where the facility has a designated parking area.
What is the storage duration?
It depends on the category: 30 days, 90 days or 180 days. The concerned authorities may set a longer period, with a minimum of 30 days. Storage must also have at least 20% spare capacity.
Does a car rental branch need ANPR or a control room?
Vehicle dealerships, showrooms and vehicle rental stores are Group A with 30 days storage, and the control room, ANPR and AI analytics are all Optional in the category table. The manual still lists mandatory coverage areas for them and the general camera, recording, security and maintenance clauses.
Do we need a maintenance contract?
The manual says the entity shall maintain an annual maintenance contract for the monitoring and control devices with a company registered by the concerned authorities, covering corrective and preventive maintenance.
Can we use cloud storage or remote access?
Not without prior approval. The manual does not permit exposing surveillance devices to the public Internet, including remote management and cloud relay, without approval from the concerned authorities, and remote maintenance must be disabled by default.
Can Quicknet help us comply in Mussafah, Abu Dhabi or Al Ain?
Yes. Quicknet is an ADMCC-approved CCTV installer with branches in Mussafah, Abu Dhabi City and Al Ain. We survey against your category, quote in writing, install or upgrade and maintain the system. Call +971 50 852 9609 or WhatsApp.
How much does the work cost?
Starting from AED 1,000+ for surveillance projects covered by the National Manual for Surveillance Systems (CCTV installation or compliance upgrade, ANPR, AI video analytics, recording and storage). This is a starting reference, not a fixed price. The final price depends on the facility category, equipment, camera quantity and project scope.