What the manual is
The National Manual for Surveillance Systems V3.0 (2026) is a unified technical and regulatory framework. Its stated objectives include defining technical standards, improving control room efficiency, defining operational controls, enabling technical inspection and approvals, and supporting AI in surveillance. The cover lists the concerned authorities, including Abu Dhabi Police and the Security Industry Regulatory Agency (SIRA); the disclaimer says the document belongs to the Monitoring and Control Centre (MCC).
Section 4 says the listed government and private entities shall comply with the manual, and that the design, installation, operation and maintenance of surveillance systems shall be carried out by one of the entities licensed by the concerned authorities.
Read this first: the disclaimer says the Arabic text prevails if it differs from the English, and that MCC may modify the manual at any time without notice. This page is an installer summary, not legal advice. Confirm the current version and your category with the MCC. The MCC notification we reviewed refers to the “National Guide for Video Surveillance Systems”; this page summarises the National Manual for Surveillance Systems V3.0 (2026), so ask the MCC which version applies to you. The disclaimer also says the concerned authorities may ask for added coverage areas or more cameras, and that the entity bears all resulting costs.
The 33 categories: storage days, control room, ANPR and AI
Each row is copied from the category table. Mandatory and Optional are the manual's own words. Some rows carry a limit, for example hospitals only or entertainment venues only. The manual adds that the concerned authorities may add categories, may set longer storage (minimum 30 days) and may change the control room, ANPR and AI requirements, and that the ANPR requirement applies only where the facility has a designated parking area.
| # | Category | Group | Storage | Control room | ANPR | AI analytics | Our page |
|---|---|---|---|---|---|---|---|
| 1 | Monetary and financial institutions (bonds and cheques) | A | 30 days | Optional | Optional | Optional | - |
| 2 | Stores and warehouses of precious, hazardous and medical materials | A | 30 days | Optional | Optional | Optional | Page 1Page 2 |
| 3 | Commercial stores specified by the concerned authorities | A | 30 days | Optional | Optional | Optional | Page 1 |
| 4 | Key cutting stores | A | 30 days | Optional | Optional | Optional | - |
| 5 | Vehicle dealerships, showrooms and vehicle rental stores | A | 30 days | Optional | Optional | Optional | Page 1Page 2 |
| 6 | Government authorities | A | 30 days | Mandatory | Optional | Optional | Page 1 |
| 7 | Wedding and events halls | A | 30 days | Optional | Optional | Optional | Page 1 |
| 8 | Cinema complexes | A | 30 days | Mandatory | Optional | Optional | Page 1 |
| 9 | Money exchangers | A | 90 days | Optional | Optional | Optional | Page 1 |
| 10 | Educational entities (nurseries, kindergartens, schools, colleges, universities) | A | 90 days | Mandatory (Except nurseries) | Mandatory (Except nurseries) | Mandatory (Except nurseries) | Page 1Page 2 |
| 11 | Precious metals and gemstones manufacturing, sales and repair stores | A | 90 days | Optional | Optional | Optional | Page 1 |
| 12 | Public gathering spaces and parks | A | 30 days | Optional | Optional | Optional | - |
| 13 | Marinas, slipways, boat and ship docks, ferry terminals, water taxi stations | A | 30 days | Optional | Optional | Optional | Page 1 |
| 14 | Bus stop shelters | A | 30 days | Optional | Optional | Optional | - |
| 15 | Entertainment venues, gaming centres, food truck areas, sports clubs | A | 30 days | Mandatory (Entertainment venues only) | Mandatory (Entertainment venues only) | Mandatory (Entertainment venues only) | Page 1Page 2 |
| 16 | Football sports stadiums | A | 30 days | Mandatory | Mandatory | Mandatory | Page 1 |
| 17 | Healthcare entities (hospitals, centres, clinics, pharmacies, blood banks) | A | 30 days | Mandatory (Public and private hospitals) | Mandatory (Public and private hospitals) | Mandatory (Public and private hospitals) | Page 1Page 2Page 3 |
| 18 | Buildings designated for vehicle parking | A | 30 days | Optional | Mandatory | Optional | Page 1Page 2 |
| 19 | Residential compounds, buildings and commercial buildings | A | 90 days | Optional | Mandatory | Optional | Page 1 |
| 20 | Fuel stations, EV charging stations, vehicle inspection centres | A | 90 days | Optional | Mandatory (Fuel and EV charging stations only) | Mandatory (Fuel and EV charging stations only) | Page 1 |
| 21 | Exhibition halls | A | 90 days | Mandatory | Mandatory | Mandatory | Page 1 |
| 22 | Labor accommodation | A | 90 days | Mandatory | Mandatory | Mandatory | Page 1 |
| 23 | Places of worship and religious educational centres | A | 30 days | Optional | Optional | Optional | Page 1 |
| 24 | Holiday homes | A | 30 days | Optional | Optional | Optional | Page 1 |
| 25 | Firearm stores and warehouses | A | 30 days | Optional | Optional | Optional | - |
| 26 | Shooting ranges | A | 180 days | Mandatory | Mandatory | Mandatory | - |
| 27 | Public welfare associations | A | 30 days | Optional | Optional | Optional | - |
| 28 | Museums | B | 90 days | Mandatory | Mandatory | Mandatory | Page 1 |
| 29 | Places of public transport and ports | B | 90 days | Mandatory | Mandatory | Mandatory | Page 1 |
| 30 | Hotels, hotel apartments and limited residential accommodation | B | 180 days | Mandatory | Mandatory | Mandatory | Page 1 |
| 31 | Shopping malls | B | 180 days | Mandatory | Mandatory | Mandatory | Page 1 |
| 32 | Banks | B | 180 days | Optional | Optional | Mandatory | Page 1 |
| 33 | Digital data storage and video recording centres | B | 180 days | Mandatory | Optional | Optional | Page 1 |
What the two groups change
Categories 1 to 27 are Group A and categories 28 to 33 (museums, public transport and ports, hotels, shopping malls, banks, data and video recording centres) are Group B. Most clauses apply to both. The tick columns show that these clauses apply to Group B only:
- Recording storage on at least RAID 5 with enterprise drives of at least 7200 RPM, 30 days of failover storage, one failover server for every four recording servers, no single point of failure and failover within two minutes
- Continuous 24/7 recording (Group A may use motion-based recording with a 10-second pre-event buffer, but identification cameras must always record continuously)
- A Windows-based video management system that supports multicast streams, layer 3 stackable core switches, and physical tamper sensors on the main racks
- Alerts for repeated failed logins, a tamper-proof audit trail forwarded to a SIEM or SOC, protection of exported files, vendor security documentation, and a secure backup of configurations
Group A (including vehicle rental, showrooms, schools, hospitals, residential buildings, parking, fuel stations and labour accommodation) still carries the core camera, recording, security and maintenance clauses below.
Cameras, recording and storage at a glance
| Area | What the manual says |
|---|---|
| Cameras | Fixed IP cameras only; minimum 1920 x 1080; infrared; varifocal motorised lens for identification cameras or when mounted at 4 m or above; dual streams; ONVIF Profile S; SNMP v3 (v1 and v2c prohibited); H.264 or newer; WDR 110 dB or equivalent; auto iris or equivalent; IP66 for outdoor. Adding or removing a camera needs prior approval from the concerned authorities. |
| Pixel density | Identification 500 pixels per metre; recognition 125; observation 63.5; detection 30; vehicle view and ANPR 500. |
| Frame rate | Identification, vehicle view and ANPR 25 fps; recognition, observation and detection 12 fps. |
| Recording | Supported operating system, ONVIF, integration with the concerned authority systems through API or SDK (supplier bears the development cost), more than two NVRs managed through a central management system (Group A clause), dedicated LAN port, camera name, date and time on the stream, CSV/TXT reports, export playable in free Windows software, automatic resume after a power cut, first in first out overwrite. |
| Storage | Capacity for the retention period plus at least 20% spare. Retention is the number of days in the category table (30, 90 or 180). |
| Power and display | UPS for the monitoring and control system with at least 30 minutes of operation; monitoring screens of at least 21 inches built for 24/7 use. |
| Network | MAC address filtering and unused ports disabled; SNMP v3 on switches; a surveillance network dedicated to and isolated from other networks. |
Monitoring and control room rules
The control room is Mandatory only for the categories marked so in the table above. Where it is required, the manual sets these rules:
- Access is restricted to employees, system operators and authorised visitors; photography is prohibited inside.
- A record of entry and exit (date and time) of employees, operators and authorised visitors.
- Internal and external communication systems and a dedicated hotline to the competent authorities for reporting incidents.
- Compliance with health and safety requirements; the room is isolated from visitor gathering areas, reception areas and crowded corridors.
- A door access control system and surveillance cameras inside the room.
- No camera-equipped electronic devices inside (mobile phones, tablets, smartwatches); no laptop without prior approval; no device removed without prior approval.
- Backup power for the room for 30 minutes in a major power failure, and a UPS for the monitoring and control system of at least 30 minutes.
Operational controls, security and maintenance
- Annual maintenance contract: the entity shall keep an annual maintenance contract for the monitoring and control devices with a company registered by the concerned authorities, covering both corrective and preventive maintenance.
- Faults: inform the concerned authorities of a technical issue and solve it within one working day; if it cannot be fixed, say why.
- Cleaning and records: clean indoor and outdoor cameras periodically and record all maintenance and cleaning work with names, date and time.
- Signage: a visible sign in Arabic, English and Urdu, with icons, that is kept in good condition.
- Drawings and documents: DWG drawings on request, cameras named on the drawings, colour-coded fields of view, as-built drawings, cable routing, network diagram, operating manual and configuration details.
- Footage: extracting footage needs an official letter from the competent or concerned authorities; deleting footage needs prior approval; keep a record of every extraction.
- Restrictions: hidden cameras are prohibited; wireless cameras, audio recording, PTZ cameras and fields of view beyond the entity boundary need prior approval; cameras must support privacy masking.
- Cyber security: no exposure to the public Internet and no cloud use without prior approval; remote maintenance disabled by default; unique non-default credentials; passwords of at least 11 characters; role-based access; lockout after more than five failed attempts; NTP set to UAE time (UTC +4); firmware and antivirus kept current.
Automatic number plate recognition requirements
The ANPR requirement is Mandatory for educational entities (except nurseries), football stadiums, hospitals, buildings designated for vehicle parking, residential compounds and buildings, fuel and EV charging stations, exhibition halls, labour accommodation, shooting ranges, museums, public transport and ports, hotels and shopping malls, and only where a designated parking area exists. For the other categories it is Optional.
- Fixed IP cameras, ONVIF Profile S, IP66 outdoor, at least 1920 x 1080, at least 25 fps (PAL) or 30 fps (NTSC), infrared
- One of three architectures: centralised on-premises server, edge AI device, or smart camera with embedded ANPR
- Accuracy of at least 99% for vehicle detection and 98% for plate recognition, day and night, for GCC plates; new plates added within 90 days
- Search by camera, plate number, source, code, colour, category, date and time; CSV reports with vehicle and plate images; images stored as JPEG
- Alerts for camera failure, processing unit failure, network failure, storage threshold, CPU or memory threshold and data backlog
- Integration with the concerned authority systems through API or SDK; UPS of at least 30 minutes; cloud only with prior approval; maintenance and cleaning recorded
AI video analytics requirements
AI analytics is Mandatory for educational entities (except nurseries), entertainment venues, football stadiums, hospitals, fuel and EV charging stations, exhibition halls, labour accommodation, shooting ranges, museums, public transport and ports, hotels, shopping malls and banks. For the other categories it is Optional.
- Approved architectures: centralised server (CPU or GPU), dedicated AI appliance, or edge AI cameras
- Deployed inside the surveillance network only; all event video, analytics data and metadata stored on-premises in the control room; cloud or external hosting only with prior written approval
- At least 90% detection accuracy, working in day, night, low-light and infrared; calibration and masking to reduce false alarms
- Real-time notifications with date and time (NTP), camera name and location, event type and a snapshot or clip reference; at least 30 days of video and analytics data
- AES-256, TLS 1.2 or higher, role-based access and multi-factor authentication for administrators; immutable event logs
- Analytics types in the manual: face detection, people counting, motion, intrusion, loitering, violent behaviour, slip and fall, dangerous objects, crowd, fire, unauthorised parking, wrong-way driving, camera tampering, and object left or removed
See our AI video analytics page and AI CCTV page.
Mandatory coverage areas and levels
Every entity must cover the mandatory public areas at the stated level: identification for entrances and exits, emergency exits, control rooms and main equipment racks, cash handling areas and safes; recognition for lobbies, corridors, lifts and stairs, loading areas, kitchens and similar areas; observation for the building perimeter, ramps and assembly areas; detection for landscape and parking areas; and vehicle view or plate reading for vehicle entrances and exits and passenger drop-off. Store rooms, utility rooms, back-of-house areas and similar spaces are optional operational coverage. Section 3 then lists extra areas for each category.
Extra coverage areas for your category
Section 3 lists extra areas for each category on top of the general mandatory areas. The number after each category is its number in the table above. Rooms and areas not listed are optional operational coverage.
| Category | Level | Area | Status |
|---|---|---|---|
| Commercial stores specified by the authorities (3) | Recognition | Inside the liquor storage area | Mandatory |
| Warehouses of precious, hazardous and medical materials (2) | Recognition | Full coverage of stores and warehouses, including between racks and shelves, and the surrounding area | Mandatory |
| Money exchangers (9) | Recognition | General coverage of teller counters | Mandatory |
| Money exchangers (9) | Recognition | All offices (single and shared) | Optional |
| Educational entities (10) | Recognition | Sleeping and food preparation areas in kindergartens and nurseries | Mandatory |
| Educational entities (10) | Recognition | All educational rooms in nurseries, kindergartens, schools, colleges, universities and institutions | Mandatory |
| Educational entities (10) | Recognition | Multipurpose halls and rooms | Mandatory |
| Educational entities (10) | Recognition | Supervisor and teacher offices | Optional |
| Precious metals and gemstones stores (11) | Recognition | General shop coverage including display tables, showcases and selling areas; precious items stores; workshops | Mandatory |
| Precious metals and gemstones stores (11) | Recognition | Trial rooms | Optional |
| Healthcare entities (17) | Recognition | Inside the pharmacy, blood banks, drug warehouse and all medical stores; ambulance drop-off area; infant nursery rooms; nursing stations; medical records room | Mandatory |
| Healthcare entities (17) | Recognition | Sterilization (CSSD) rooms; physiotherapy rooms (men and children only) | Optional |
| Buildings for vehicle parking (18) | Identification | Pedestrian entrances to the building | Mandatory |
| Buildings for vehicle parking (18) | Detection | Inside the building to cover the vehicle parking area; internal driveways | Mandatory |
| Residential compounds and buildings, commercial buildings (19) | Detection | Public places available to the public; internal driveways of residential compounds | Mandatory |
| Fuel stations, EV charging stations, vehicle inspection centres (20) | Identification | Entrances and exits of convenience stores; main tank refuelling points (petrol, diesel, gas); lube stores | Mandatory |
| Fuel stations, EV charging stations, vehicle inspection centres (20) | Recognition | Dispenser fuelling points; inside the convenience store; car wash and vacuum bay; lube bay; vehicle inspection areas; EV charging area; indoor seating; drive-through of convenience stores | Mandatory |
| Fuel stations, EV charging stations, vehicle inspection centres (20) | Detection | Internal driveways | Mandatory |
| Labor accommodation (22) | Recognition | Laundry room; training room | Mandatory |
| Hotels and limited residential accommodation (30) | Identification | Passengers' entrances and exits of boat docks | Mandatory |
| Hotels and limited residential accommodation (30) | Recognition | General outdoor coverage of villas and chalets; boats and marina pavements; baggage and valuables rooms | Mandatory |
| Banks (32) | Recognition | General coverage of the teller counter | Mandatory |
| Banks (32) | Recognition | All offices (single and shared) | Optional |
| Digital data storage and video recording centres (33) | Recognition | The entire data centre hall including between racks and the video recording centre; UPS, battery and generator rooms; server room; network operations centre | Mandatory |
| Digital data storage and video recording centres (33) | Recognition | BMS rooms, ELV rooms and transformer rooms | Optional |
Required AI analytics for specific categories
Besides the general analytics for all categories (section 5, part 2.1), the manual lists these analytics for specific categories. They matter where AI analytics is Mandatory.
| Category | Analytics | Areas of application |
|---|---|---|
| Educational entities (10) | Violent behaviour detection; dangerous objects detection | All educational rooms; indoor and outdoor play areas (violent behaviour also in multipurpose halls) |
| Entertainment venues (15) | Object left or removed detection; slip and fall detection | Indoor and outdoor playing areas; audience seating area |
| Football sports stadiums (16) | Violent behaviour; dangerous objects; object left or removed | Audience seating area |
| Healthcare entities (17) | Motion detection; unauthorised parking detection | Medical records room; ambulance drop-off area |
| Fuel stations, EV charging stations, vehicle inspection centres (20) | Object left or removed detection; unauthorised parking detection | Dispenser fuelling points; main tank refuelling points (petrol, diesel, gas) |
| Museums and exhibition halls (21, 28) | Motion detection; violent behaviour; dangerous objects; object left or removed | Precious material stores (motion); indoor and outdoor venues, galleries and exhibition areas |
| Shooting ranges (26) | Motion detection; violent behaviour detection | Weapon and ammunition stores (motion); shooting cabins, indoor and outdoor shooting areas, training areas |
| Hotels and limited residential accommodation (30) | Face detection | Visitors' entrances and exits of boat docks |
What does the work cost?
Starting from AED 1,000+ for surveillance projects covered by the National Manual for Surveillance Systems: CCTV installation or compliance upgrade, ANPR, AI video analytics, and recording and storage. This is a starting reference, not a fixed price, and it applies only to these manual-related projects, not to other Quicknet services. The final price depends on the facility category, equipment, camera quantity and project scope, and is confirmed in a written quotation after the site survey.
How Quicknet helps in Mussafah, Abu Dhabi and Al Ain
Quicknet Computers is an ADMCC-approved CCTV installer with branches in Mussafah, Abu Dhabi City and Al Ain, in business since 2012. We survey your premises against your category, quote in writing, install and upgrade IP cameras, NVRs and storage, supply the supporting network cabling and door access works, and keep the system under an annual maintenance contract. No price is published here because it depends on the category, the camera count and the scope.
Request a CCTV site survey and quotation
Tell us about the facility. A few details let us prepare the right scope before the survey. Starting from AED 1,000+ for manual-related surveillance projects; the final price depends on the facility category, equipment, camera quantity and project scope.
CCTV survey and quotation request
Prefer to talk? Mobile / WhatsApp: +971 50 852 9609 · Landline: +971 2 553 1474