Connector Types at a Glance
Pick the connector by the cable it terminates. Copper and fibre never share a connector.
| Connector | Cable | Where it is used |
|---|---|---|
| RJ45 plug | Copper (Cat5e to Cat6A, Cat8) | On patch cords between the patch panel and the switch, and between the wall outlet and the device |
| RJ45 keystone jack | Copper | Permanent termination at the wall faceplate and in the patch panel; the standard 2026 office arrangement |
| GG45 / TERA | Copper Cat7 and Cat7A | Rare; specific industrial or healthcare imaging projects, ISO standard only |
| LC | Fibre, single-mode and multi-mode | Small-form-factor connector on fibre patch panels and switch transceivers |
| SC | Fibre | Larger push-pull connector on fibre patch panels |
| ST | Fibre | Older bayonet-style connector, still found on existing links |
| MTP / MPO | Multi-fibre trunks (12 and 24 strand) | Pre-terminated trunks for data-centre patching |
RJ45 Plug vs Keystone Jack
- The jack stays, the cord moves. The in-wall cable is terminated once on a keystone jack at the outlet and on a keystone patch panel in the rack. Patch cords with RJ45 plugs then connect the jack to the device and the panel to the switch.
- Do not crimp plugs onto the in-wall cable. Field-crimped plugs straight onto switch ports with no patch panel, and cable lengths with no logic, are what ad-hoc cabling looks like and they cannot be certified like a permanent link.
- Match the connector to the category. A Cat6A link needs Cat6A-rated jacks and cords end to end; a Cat6 jack in a Cat6A link limits the link.
- Length. The permanent link is 90 metres plus up to 10 metres of patch cord, 100 metres in all.
Fibre Connectors and How They Are Terminated
LC vs SC. Both are used on fibre patch panels. LC is the smaller connector and is the usual choice on switch transceivers; SC is larger and push-pull. Both come in single-mode and multi-mode versions, so match the connector and fibre type (OS2 or OM3/OM4/OM5) at both ends.
| Termination | Loss | Best for |
|---|---|---|
| Fusion splice with a factory-terminated pigtail | Lowest loss, most reliable | Required for OS2 single-mode and any tender-grade install |
| Field-mount (mechanical) LC, SC or ST | Slightly higher loss, 0.5 to 1 dB | Low-volume terminations and emergency repairs |
| Pre-terminated MTP/MPO trunks and cassettes | Factory-terminated | Data-centre patching between racks |
Every fibre link is then tested with an OTDR or a loss test set. See our single-mode vs multi-mode guide.
Testing Connectors After Installation
Copper links are certified with a cable analyser (Fluke), which measures wire map, length, insertion loss, NEXT and return loss. Fibre links are tested with an OTDR, which shows loss and reflection events at splices and connectors, and an OLTS, which measures total insertion loss. A loose or dirty connector shows up in these tests, which is why every link is documented. See cable testing and certification.
What Quicknet Does
Quicknet Computers terminates copper on keystone jacks and patch panels and fibre by splicing or pre-terminated cassettes, then tests, labels and documents each link. We work in Abu Dhabi, Mussafah and Al Ain, and in Dubai on a project basis. See structured cabling in Abu Dhabi, fibre optic cabling, Al Ain and cabling cost per point.