Network Cable Connector Types: RJ45, LC, SC, ST and MPO Explained

Which connector goes on which cable: the RJ45 plug and keystone jack for copper, LC, SC, ST and MPO for fibre, how they are terminated and what a certified link needs.

Get a Free Quote   📞 Book a Site Survey

By Quicknet Engineering Team, Quicknet Computers · Reviewed by Jenson Cleetus · Published: 19 November 2026 · Last reviewed: 19 November 2026
✅ Plain-language guide ✅ Last reviewed 19 November 2026 ✅ Abu Dhabi and Al Ain ✅ ISO 9001:2015 & ICV Certified
At a Glance

Connector Types at a Glance

Pick the connector by the cable it terminates. Copper and fibre never share a connector.

Network cable connector types and where they are used.
ConnectorCableWhere it is used
RJ45 plugCopper (Cat5e to Cat6A, Cat8)On patch cords between the patch panel and the switch, and between the wall outlet and the device
RJ45 keystone jackCopperPermanent termination at the wall faceplate and in the patch panel; the standard 2026 office arrangement
GG45 / TERACopper Cat7 and Cat7ARare; specific industrial or healthcare imaging projects, ISO standard only
LCFibre, single-mode and multi-modeSmall-form-factor connector on fibre patch panels and switch transceivers
SCFibreLarger push-pull connector on fibre patch panels
STFibreOlder bayonet-style connector, still found on existing links
MTP / MPOMulti-fibre trunks (12 and 24 strand)Pre-terminated trunks for data-centre patching
Copper

RJ45 Plug vs Keystone Jack

  • The jack stays, the cord moves. The in-wall cable is terminated once on a keystone jack at the outlet and on a keystone patch panel in the rack. Patch cords with RJ45 plugs then connect the jack to the device and the panel to the switch.
  • Do not crimp plugs onto the in-wall cable. Field-crimped plugs straight onto switch ports with no patch panel, and cable lengths with no logic, are what ad-hoc cabling looks like and they cannot be certified like a permanent link.
  • Match the connector to the category. A Cat6A link needs Cat6A-rated jacks and cords end to end; a Cat6 jack in a Cat6A link limits the link.
  • Length. The permanent link is 90 metres plus up to 10 metres of patch cord, 100 metres in all.
Fibre

Fibre Connectors and How They Are Terminated

LC vs SC. Both are used on fibre patch panels. LC is the smaller connector and is the usual choice on switch transceivers; SC is larger and push-pull. Both come in single-mode and multi-mode versions, so match the connector and fibre type (OS2 or OM3/OM4/OM5) at both ends.

Fibre termination methods.
TerminationLossBest for
Fusion splice with a factory-terminated pigtailLowest loss, most reliableRequired for OS2 single-mode and any tender-grade install
Field-mount (mechanical) LC, SC or STSlightly higher loss, 0.5 to 1 dBLow-volume terminations and emergency repairs
Pre-terminated MTP/MPO trunks and cassettesFactory-terminatedData-centre patching between racks

Every fibre link is then tested with an OTDR or a loss test set. See our single-mode vs multi-mode guide.

Testing

Testing Connectors After Installation

Copper links are certified with a cable analyser (Fluke), which measures wire map, length, insertion loss, NEXT and return loss. Fibre links are tested with an OTDR, which shows loss and reflection events at splices and connectors, and an OLTS, which measures total insertion loss. A loose or dirty connector shows up in these tests, which is why every link is documented. See cable testing and certification.

Quicknet

What Quicknet Does

Quicknet Computers terminates copper on keystone jacks and patch panels and fibre by splicing or pre-terminated cassettes, then tests, labels and documents each link. We work in Abu Dhabi, Mussafah and Al Ain, and in Dubai on a project basis. See structured cabling in Abu Dhabi, fibre optic cabling, Al Ain and cabling cost per point.

Sources

Sources

Connector details come from our category comparison, fibre guide and structured cabling guide.

Last reviewed 19 November 2026. Confirm connector types for your equipment with the equipment datasheet.

FAQ

Network Connector Types: FAQs

What are the types of network cable connectors?
For copper the connector is the RJ45 plug on patch cords and the RJ45 keystone jack at outlets and patch panels, with GG45 or TERA for Cat7. For fibre the common connectors are LC, SC and ST, and MTP/MPO for multi-fibre data-centre trunks.
What is the difference between an RJ45 plug and a keystone jack?
The RJ45 plug is the connector on the end of a patch cord. The keystone jack is the socket the in-wall cable is permanently terminated on, at the wall faceplate and in the patch panel. The cord plugs into the jack.
What is the difference between LC and SC connectors?
Both connect fibre on patch panels. LC is the smaller connector and is the usual choice on switch transceivers; SC is larger and push-pull. Use the same fibre type (single-mode or multi-mode) at both ends.
What is an MTP or MPO connector?
MTP/MPO is a multi-fibre connector used on pre-terminated 12-strand and 24-strand trunks for data-centre patching between racks.
What is the difference between fusion splicing and a mechanical connector?
A fusion splice joins a factory-terminated pigtail to the cable with the lowest loss and is required for OS2 single-mode and tender-grade installs. Mechanical field-mount LC, SC or ST connectors are quicker and cheaper but have slightly higher loss, 0.5 to 1 dB.
Should RJ45 plugs be crimped onto in-wall cable?
No. In-wall cable is terminated on keystone jacks and patch panels, and short patch cords carry the plugs. Plugs crimped directly onto switch ports are a sign of ad-hoc cabling and cannot be certified like a permanent link.
How long can a copper link with RJ45 connectors be?
The permanent link is limited to 90 metres, plus up to 10 metres of patch cord, 100 metres in all. Beyond that use fibre.
How are copper and fibre connectors tested?
Copper links are certified with a Fluke cable analyser (wire map, length, insertion loss, NEXT, return loss). Fibre links are tested with an OTDR and a loss test set, which also show connector and splice events.
Does Quicknet terminate copper and fibre connectors in Abu Dhabi and Al Ain?
Yes. Quicknet terminates copper on keystone jacks and patch panels and fibre by splicing or pre-terminated cassettes, then tests and documents every link in Abu Dhabi, Mussafah and Al Ain, and in Dubai on a project basis.

Planning a Cabling Project?

Tell us your building and the number of outlets. We survey for free, specify the cable and connectors and send an itemised written quote. Call or WhatsApp +971 50 852 9609.

Get a Free Quote ‎+971 50 852 9609‎   💬 Chat on WhatsApp